About 54 results
Open links in new tab
  1. Mini-Class: Unlocking Chapter 1 of the 2024 IBC – Scope and ...

    Oct 16, 2009 · Chapter 1 of the 2024 International Building Code (IBC) establishes the foundation for how the code is applied, enforced, and interpreted. It outlines the scope, purpose, and administrative …

  2. Egress Capacity Calculator - 2024 IBC

    Interactive calculator for means of egress using 2024 IBC Section 1005, Table 1020.3, and Section 1010.1.1 for doors.

  3. 1, single user, unisex toilet room in coffee shop, per 2021 IBC

    Feb 24, 2025 · The IBC Commentary language for exception #5 confirms this. There is also the exception under the calculations portion , 2902.1.1, reading "Distribution of the sexes is not required …

  4. Group E Occupancies Explained - IBC 305 (2024) - The Building Code …

    Oct 16, 2009 · Do you agree with the following interpretation and summary of this important section? Definition and Scope of Group E Occupancies: Group E occupancy primarily involves buildings or …

  5. 2018 IBC 1009.2.1 - Elevators Required (Accessible Means of Egress)

    Mar 31, 2021 · 2018 IBC 1009.2.1 says, "In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of …

  6. Door landing (2018 IBC 1010.1.6) - The Building Code Forum

    Apr 3, 2013 · The word "landing" is typically associated with stairs (IBC 1011.6), as discussed above. There is no specific definition of "landing" in IBC chapter 2. IBC 1010.1.1 xc. #8 says that in R-2 …

  7. Fire Separation Distance Between New and Existing Building with …

    Feb 7, 2024 · From the 2021 IBC Commentary: The Commentary says: Fire separation distance is the distance from the exterior wall of the building to one of the three following locations, measured …

  8. IBC and Park Amenities / Outdoor Spaces - The Building Code Forum

    Feb 12, 2021 · IBC 424.1: Children's Play Structures inside all occupancies covered by this code that exceed 10 feet in height and 150 sq. feet in area shall comply with 424.2 through 424.5. IBC 1004.5 …

  9. IBC 2018 Concentrated Business Occupancy - The Building Code Forum

    May 16, 2019 · With the introduction of the IBC 2018, Business occupancy has been subdivided in Table 1004.5 and then Section 1004.8. Now the occupancy for Business is 1:150 and then there is …

  10. Area of Refuge in R-2 occupancy (NFPA VS IBC) - The Building Code …

    Nov 30, 2018 · I apologies in advanced for what seems like the ramblings of a madman. NFPA turns my brain to mush and this is the result. I have a multistory R-2 building, 5 stories above grade …